|  |  The Vibration Controllers exploit the power of new generation digital signal processing techniques to deliver very high degree of control accuracy and performance in vibration test applications.
The 16/32 Bit Fixed/Floating point processors specifically designed to process complex mathematical calculations & algorithms, combined with high speed simultaneous data sampling Analog-to-Digital Converters and Digital-to-Analog Converters make the whole architecture best suitable for developing all types of vibration control applications to fulfill everyday demands of industry standards, research, Space and MIL applications worldwide. | | | | | | | Swept Sine Software Specifications | | Parameters | Model - I | Model - II | Model - III | | Frequency Range | 1 Hz – 5000 Hz | 0.1 Hz – 5000 Hz | 0.08 Hz – 5000 Hz | | Control Parameter | Constant – Acc./Vel/Disp Slope - Acceleration
| Constant – Acc./Vel/Disp.. Slope - Acc.//Vel/Disp | Constant – Acc./Vel/Disp.. Slope - Acc.//Vel/Disp | | Test Mode | Sweep Frequency Test Fixed Frequency Test (Discrete Step Control) Resonance Search & Dwell Manual Control using Keyboard DVA Monitoring (using ext. sinusoidal frequency input) | Sweep Frequency Test Fixed Frequency Test (Discrete Step Control)Resonance Search & Dwell (Optional) - - | Sweep Frequency Test Fixed Frequency Test (Discrete Step Control) Resonance Search & Dwell (Optional) - - | | Input Channels | 02/04 | 08/16 | 32, expandable upto 128 | | Channel sensitivity | 1.0 to 99.99 pC/g or mV/g | 1.0 to 1000 pC/g or mV/g | 0.1 to 10000 pC/g or mV/g | | Channel Control | Single/ Multi-channel | Single/ Multi-channel | Single/ Multi-channel | Control Mode Filters | Maximal/ Average | Maximal/ Average/ Weighted Average | Maximal/ Average/ Weighted Average | | 8th Order (analog) | Anti-aliasing (Analog/Digital) | Anti-aliasing (Analog/Digital/Tracking) | Output Channels Filters | Drive - 12V(Pk-Pk) COLA- proportional to frequency | Drive - 20V(Pk-Pk) COLA- proportional to frequency | Drive - 20V(Pk-Pk) COLA- proportional to frequency | | 8th Order (analog) | Anti-aliasing (Analog/Digital) | Anti-aliasing (Analog/Digital/Tracking) | | Digital I/O | 4 I/P, 4 O/P | 8 I/P, 8 O/P | 16 I/P, 16 O/P | | Compression Rate | 0.001 to 3.0 dB/Sec/Hz | 0.001 to 20 dB/Sec/Hz | 0.001 to 20 dB/Sec/Hz | | Compression Limit | 2.0 to 200.0 dB/s | — | — | | Control Dynamic Range | > 85 dB | > 95 dB | >105 dB | | Test Duration | Upto specified no. of sweeps or infinite. Upto specified duration of time. | Upto specified no. of sweeps. Upto specified duration of time. | Upto specified no. of sweeps. Upto specified duration of time. | | Online Display | Parameters | Parameters | Parameters | | | Frequency, Programmed Control Level, Measured Control Level, Servo Voltage, No. of sweeps elapsed/ remaining, Date , Time, Displacement/Velocity/Acceleration of each channel.
| Frequency, Programmed Control Level, Measured Control Level, Servo Voltage, No. of sweeps elapsed/ remaining, Date , Time, Displacement/Velocity/Acceleration of each channel. | Frequency, Programmed Control Level, Measured Control Level, Servo Voltage, No. of sweeps elapsed/ remaining, Date , Time, Displacement/Velocity/Acceleration of each channel. | | | Graph | Graph | Graph | | | Control Curve (Control Vs. Frequency) Drive Curve (Drive Vs. Frequency) Individual Channel Response (Channel Values Vs. Frequency) Transfer Function (Channel ‘Y’/ Channel ‘X’ Vs. Frequency) Alarm/ Abort limit region | Control Curve (Control Vs. Frequency) Drive Curve (Drive Vs. Frequency) Individual Channel Response (Channel Values Vs. Frequency) Transfer Function (Channel ‘Y’/ Channel ‘X’ Vs. Frequency) Alarm/ Abort limit region Composite Display | Control Curve (Control Vs. Frequency) Drive Curve (Drive Vs. Frequency) Individual Channel Response (Channel Values Vs. Frequency) Transfer Function (Channel ‘Y’/ Channel ‘X’ Vs. Frequency) Alarm/ Abort limit region Composite Display | Graph Annotations | Selection of Y-axis value as acceleration/Velocity/Displacement. Two lines of annotation programmable by the operator for each test to identify the test conducted. | Selection of Y-axis value as acceleration/Velocity/Displacement. Two lines of annotation programmable by the operator for each test to identify the test conducted. | Selection of Y-axis value as acceleration/Velocity/Displacement. Two lines of annotation programmable by the operator for each test to identify the test conducted. | Storage of Test Data | To disk at pre-configured intervals in tabular text format. Export of test data to Microsoft Excel. | To disk at pre-configured intervals in tabular text format. Export of test data to Microsoft Excel. | To disk at pre-configured intervals in tabular text format. Export of test data to Microsoft Excel. | Storage of Test Graph | Storage of Graph in WMF/ BMP format on mouse click. Export of test graph to Microsoft Word. | Storage of Graph in WMF/ BMP format on mouse click. Export of test graph to Microsoft Word. | Storage of Graph in WMF/ BMP format on mouse click. Export of test graph to Microsoft Word. | Posttest Report Generation | Facilitates report generation of test conducted. Export of graph to Microsoft Word. | Facilitates report generation of test conducted. Export of graph to Microsoft Word. | Facilitates report generation of test conducted. Export of graph to Microsoft Word. | Safety features/ Protections | Loop check feature to verify physical setting of the system before staring actual test. Independent alarm and abort profile in terms of + (0.5 to 20 dB) of reference test profile over the entire frequency range. Auto test shutdown in case of exceeding the maximum ‘g’ level programmed. Auto test shutdown in case of control exceeding the abort limit. Password authorization to operate the software. | Loop check feature to verify physical setting of the system before staring actual test. Independent alarm and abort profile in terms of + (0.5 to 20 dB) of reference test profile over the entire frequency range. Auto test shutdown in case of exceeding the maximum ‘g’ level programmed. Auto test shutdown in case of control exceeding the abort limit. Password authorization to operate the software. | Loop check feature to verify physical setting of the system before staring actual test. Independent alarm and abort profile in terms of + (0.5 to 20 dB) of reference test profile over the entire frequency range. Auto test shutdown in case of exceeding the maximum ‘g’ level programmed. Auto test shutdown in case of control exceeding the abort limit. Password authorization to operate the software. | | | | | | | | Broadband Random Control Software | | Parameters | Model - I | Model - II | Model - III | | Test Mode | Pseudo Random True Random | True Random | True Random | | Frequency Range | 500, 1000, 2000, 3000 or 4000 Hz | 125,250,500,1000,2000 or 4000 Hz | 31.25,62.5,125,250,500,1000,2000 or 4000 Hz | | Frequency Lines | Frequency Lines | 100, 200, 300,400 or 500 | 100, 200, 400 or 800(1600 optional) | | Input Channels | 02/04 | 08/16 | 32, expandable upto 128 | | Channel type | Selectable for Charge/ mV/ ICP | Selectable for Charge/ mV/ ICP | Selectable for Charge/ mV/ ICP | | Channel sensitivity | 1.0 to 99.99 pC/g or mV/g | 1.0 to 1000 pC/g or mV/g | 0.1 to 10000 pC/g or mV/g | | Channel Control | Single/ Multi-channel | Single/ Multi-channel | Single/ Multi-channel | Control Mode Filters | Maximal/ Average | Maximal/ Average/ Weighted Average | Maximal/ Average/ Weighted Average | | 8th Order (analog) | Anti-aliasing (Analog/Digital) | Anti-aliasing (Analog/Digital/Tracking) | Output Channels Filters | Drive - 20V (Peak-Peak) | Drive - 20V (Peak-Peak) | Drive - 20V (Peak-Peak) | | 8th Order (analog) | Anti-aliasing (Analog/Digital) | Anti-aliasing (Analog/Digital/Tracking) | | Drive Signal | Continuous Gaussian Random | Continuous Gaussian Random | Continuous Gaussian Random | | Dynamic Range | > 82 dB | > 92 dB | > 102 dB | | Limit Channel | Upto 200 Grms | Upto 200 Grms | Upto 200 Grms | | Correction Rate | 0.1 to 50.0 dB/sec | 0.1 to 50.0 dB/sec | 0.1 to 50.0 dB/sec | | Crest Factor/ Sigma Clipping | 1.8 to 8 | 2 to 8 | 2 to 8 | | Degree of Freedom | 5 to 800 | 2 to 1000 | 8 to 8000 | | Loop time (typical) | 200 mS | 100 mS | 100 mS | | Test Duration | Upto 499:59:59 Hrs | Upto 999:59:59 Hrs | Upto 9999:59:59 Hrs | | Test Profile/ Spectrum | Programmable thru tabular editor. 100 segments/ break points. Simple editing of dB/Oct or PSD/ ASD values Insertion, deletion & changes of levels & slope. Capable to virtually programme any test profile. Graphical presentation of profile for visualization. | Programmable thru tabular editor. 200 segments/ break points. Simple editing of dB/Oct or PSD/ ASD values Insertion, deletion & changes of levels & slope. Capable to virtually programme any test profile. Graphical presentation of profile for visualization. | Programmable thru tabular editor. 200 segments/ break points. Simple editing of dB/Oct or PSD/ ASD values Insertion, deletion & changes of levels & slope Capable to virtually programme any test profile. Graphical presentation of profile for visualization. | | Soft Test Startup Time | 1 to 30 seconds | 1 to 30 seconds | 1 to 30 seconds | | Soft Test Stop Time | 1 to 30 seconds | 1 to 30 seconds | 1 to 30 seconds | Pre-Test Loop to determine system response before actually starting the main test | User selectable drive level from 5 to 2000 mV rms | User selectable drive level from 0 to 1000 mV rms | User selectable drive level from 0 to 1000 mV rms | | Test Level Scheduling | User selectable : -27 to 0 dB Duration for each level can be programmed separately. | User selectable : -80 to 0 dB Duration for each level can be programmed separately. | User selectable : -80 to 0 dB Duration for each level can programmed separately. | | Online Display | Parameters: Programmed Grms, Control Grms, Individual Channel(s) Grms, Channel(s) in Use, Scheduled Test Level, Elapsed Test Period, Remaining Test Period, Drive Voltage (rms), Time & Date.
Graph: Control/ Reference test spectra (g2/Hz Vs. Frequency) Individual channel spectra (g2/Hz Vs. Frequency) Overlaid Spectra ((g2/Hz Vs. Frequency) Transfer function spectra CHx/CHy ( dB Vs. Frequency) Drive spectra ( dB Vs. Frequency) Drive signal ( Volt Vs. Frequency) Alarm/ Abort limits in all spectra. Display Format: Log or linear scale. Alarm & Abort line display. X & Y-axis grid enable/ disable | Parameters: Programmed Grms, Control Grms, Individual Channel(s) Grms, Channel(s) in Use, Scheduled Test Level, Elapsed Test Period, Remaining Test Period, Drive Voltage (rms), Time & Date.
Graph: Control/ Reference test spectra (g2/Hz Vs. Frequency) Individual channel spectra (g2/Hz Vs. Frequency) Overlaid Spectra ((g2/Hz Vs. Frequency) Transfer function spectra CHx/CHy ( dB Vs. Frequency) Drive spectra ( dB Vs. Frequency) Drive signal ( Volt Vs. Frequency) Alarm/ Abort limits in all spectra. Display Format: Log or linear scale. Alarm & Abort line display. X & Y-axis grid enable/ disable | Parameters: Programmed Grms, Control Grms, Individual Channel(s) Grms, Channel(s) in Use, Scheduled Test Level, Elapsed Test Period, Remaining Test Period, Drive Voltage (rms), Time & Date.
Graph: Control/ Reference test spectra (g2/Hz Vs. Frequency) Individual channel spectra (g2/Hz Vs. Frequency) Overlaid Spectra ((g2/Hz Vs. Frequency) Transfer function spectra CHx/CHy ( dB Vs. Frequency) Drive spectra ( dB Vs. Frequency) Drive signal ( Volt Vs. Frequency) Alarm/ Abort limits in all spectra. Display Format: Log or linear scale. Alarm & Abort line display. X & Y-axis grid enable/ disable | Graph Annotations to identify the test conducted | Two lines of annotation programmable by the operator for each test | User configurable message/ notes | User configurable message/ notes | | Storage of Test Data | To disk at pre-configured intervals in tabular text format. Export of test data to Microsoft Office | To disk at pre-configured intervals in tabular text format. Export of test data to Microsoft Office | To disk at pre-configured intervals in tabular text format. Export of test data to Microsoft Office | | Posttest Report Generation | Tabular data for PSD Vs. Frequency Control/ Reference spectrum Control test spectra (g2/Hz Vs. Frequency) Individual channel spectra (g2/Hz Vs. Frequency) Overlaid Spectra ((g2/Hz Vs. Frequency) Transfer function spectra CHx/CHy ( dB Vs. Frequency) Drive spectra ( dB Vs. Frequency) | Tabular data for PSD Vs. Frequency Control/ Reference spectrum Control test spectra (g2/Hz Vs. Frequency) Individual channel spectra (g2/Hz Vs. Frequency) Overlaid Spectra ((g2/Hz Vs. Frequency) Transfer function spectra CHx/CHy ( dB Vs. Frequency) Drive spectra ( dB Vs. Frequency) | Tabular data for PSD Vs. Frequency Control/ Reference spectrum Control test spectra (g2/Hz Vs. Frequency) Individual channel spectra (g2/Hz Vs. Frequency) Overlaid Spectra ((g2/Hz Vs. Frequency) Transfer function spectra CHx/CHy ( dB Vs. Frequency) Drive spectra ( dB Vs. Frequency) | | Safety features | Loop check for proper physical connections. Check of programming values limits. Password authorization for secured operation. Max. ‘Grms' limit for each channel. No. of lines for line abort No. of loops for line abort | Loop check for proper physical connections. Check of programming values within limits. Password authorization for secured operation. Max. ‘Grms' limit for each channel. No. of lines for line abort No. of loops for line abort | Loop check for proper physical connections. Check of programming values within limits. Password authorization for secured operation. Max. ‘Grms' limit for each channel. No. of lines for line abort No. of loops for line abort | | | | | Classical Shock Controller/Arbitrary Transient / SRS Analysis & Synthesis | | Parameters | Model - I | Model - II | Model - III | | Modes of Operation | Half Sine Triangular Forward Saw-tooth Backward Saw-tooth Rectangular | Half Sine Triangular Forward Saw-tooth Backward Saw-tooth Rectangular Trapezoidal Arbitrary Transient SRS Analysis & Synthesis | Half Sine Triangular Forward Saw-tooth Backward Saw-tooth Rectangular Trapezoidal User defined shapes Arbitrary Transient SRS Analysis & Synthesis | | Pulse amplitude | 1 to 200 ‘g' | 0.1 to 200 ‘g' | 0.1 to 500 ‘g' | | Pulse width | 0.5 to 50 mS | 0.1 to 100 mS | 0.1 to 1000 mS | Pre & Post Pulse Amplitude ( % of Pulse Amplitude | 5.0% to 50.0%(sine) | 5.0% to 50.0%(sine, rectangular) | 5.0% to 50.0%(sine, rectangular) | | Input Channels | 02/04 | 08/16 | 32, expandable upto 128 | | Channel sensitivity | 1.0 to 99.99 pC/g or mV/g | 1.0 to 1000 pC/g or mV/g | 0.1 to 10000 pC/g or mV/g | | Channel Control | Single/ Multi-channel | Single/ Multi-channel | Single/ Multi-channel | Control Mode
| Maximal/ Average | Maximal/ Average/ Weighted Average | Maximal/ Average/ Weighted Average | | Filters | 8th Order (analog) | Anti-aliasing (Analog/Digital) | Anti-aliasing (Analog/Digital/Tracking) | | Control Mode | Average | Average/Maximal/Weighted | Average/Maximal/Weighted | | Channel Selection | Disable/Monitor /Control & Monitor | Disable/Monitor /Control & Monitor | Disable/Monitor /Control & Monitor | | Output Channel | 8th Order (Analog) | Anti-aliasing (Analog/Digital) | Anti-aliasing (Analog/Digital/Tracking) | | Filters | 4 I/P, 4 O/P | 8 I/P, 8 O/P | 16 I/P, 16 O/P | Pre-Test Amplitude (% of Reference Amplitude) | 10.0% to 50.0% Pre-test is carried out to determine response/ transfer function of the Vibration System by sending a low level signal. This feature expedites the equalization process at the time of actual testing and safeguards the product from getting over tested due to pulses consumed in equalization. | 5% to 50.0% Pre-test is carried out to determine response/ transfer function of the Vibration System by sending a low level signal. This feature expedites the equalization process at the time of actual testing and safeguards the product from getting over tested due to pulses consumed in equalization | 5% to 50.0% Pre-test is carried out to determine response/ transfer function of the Vibration System by sending a low level signal. This feature expedites the equalization process at the time of actual testing and safeguards the product from getting over tested due to pulses consumed in equalization | | Pulse Repetition Rate | 50.0 to 3000 mS | 20.0 to 3000 mS | 10.0 to 5000 mS | Total no. of pulses to be generated | 1 to 100000 | 1 to 100000 | 1 to 100000 | | Online Display | Parameters: Pulse Width, Reference Pulse Amplitude (g), Control Pulse Amplitude (g), Drive Signal (V), Total Pulse, Pulse Elapsed, Pulse Remaining, Individual Channel Level, Channel Mode (Control/ Monitor), Displacement (mm), Velocity (mm/s), Date, Time.
Graph: Control graph (g vs. time), Individual channel graph (g vs. time), Drive graph (volt vs. time), Alarm/ Abort limit region | Parameters: Pulse Width, Reference Pulse Amplitude (g), Control Pulse Amplitude (g), Drive Signal (V), Total Pulse, Pulse Elapsed, Pulse Remaining, Individual Channel Level, Channel Mode (Control/ Monitor), Displacement (mm), Velocity (mm/ s), Date, Time.
Graph: Control graph (g vs. time), Individual channel graph (g vs. time), Drive graph (volt vs. time), Alarm/ Abort limit region | Parameters: Pulse Width, Reference Pulse Amplitude (g), Control Pulse Amplitude (g), Drive Signal (V), Total Pulse, Pulse Elapsed, Pulse Remaining, Individual Channel Level, Channel Mode (Control/ Monitor), Displacement (mm), Velocity (mm/s), Date, Time.
Graph: Control graph (g vs. time), Individual channel graph (g vs. time), Drive graph (volt vs. time), Alarm/ Abort limit region | | Graph Annotations | Two lines of annotation programmable by the operator for each test to identify the test conducted. | User configurable message/ notes | User configurable message/ notes | | Storage of Test Data | To disk at pre-configured intervals in tabular text format & waveforms | To disk at pre-configured intervals in tabular text format & waveforms | To disk at pre-configured intervals in tabular text format & waveforms | | Storage of Test Graph | Storage of waveform into user defined file. Export of test graph to Microsoft Office | Storage of waveform into user defined file. Export of test graph to Microsoft Office | Storage of waveform into user defined file. Export of test graph to Microsoft Office | | Posttest Report Generation | Facilitates report generation of test conducted. Export of graph to Microsoft Office | Facilitates report generation of test conducted. Export of graph to Microsoft Office | Facilitates report generation of test conducted. Export of graph to Microsoft Office | Safety features/ Protections | Loop check feature thru Pre-test to verify physical setting of the system before starting actual test. Independent alarm and abort profile in terms of ± (1.0 to 50.0 %) of reference pulse acceleration. Auto test shutdown in case of control exceeding the abort limit or lines exceeds for set no. of loops. Limiting abort level Grms on each channel. Password authorization to operate the software. | Loop check feature thru Pre-test to verify physical setting of the system before starting actual test. Independent alarm and abort profile in terms of ± (1.0 to 50.0 %) of reference pulse acceleration. Auto test shutdown in case of control exceeding the abort limit or lines exceeds for set no. of loops. Limiting abort level Grms on each channel. Password authorization to operate the software. | Loop check feature thru Pre-test to verify physical setting of the system before starting actual test. Independent alarm and abort profile in terms of ± (1.0 to 50.0 %) of reference pulse acceleration. Auto test shutdown in case of control exceeding the abort limit or lines exceeds for set no. of loops. Limiting abort level Grms on each channel. Password authorization to operate the software. | | | | | | | | | | Random-on-Random Control Software | | Parameters | Model - I | Model - II | Model - III | | Independent no. of narrowband profile | —- | 1 to 10 | 1 to 10 | | Drive Signal | —- | Swept narrowband Gaussian random combined with broadband Gaussian random | Swept narrowband Gaussian random combined with broadband Gaussian random | | Breakpoint table | —- | Constant/ variable | Constant/ variable | | Sweep Rate | —- | Oct/min or Hz/sec or time/sec | Oct/min or Hz/sec or time/sec | | Star frequency | —- | Any value between the available frequency range | Any value between the available frequency range | | Start direction | —- | Up/down | Up/down | | Run Schedule | —- | Broadband random on/off, Narrowband sweeping on/off Narrowband on/off | Broadband random on/off, Narrowband sweeping on/off Narrowband on/off | | Safety | —- | User configurable ramp up rate in dB/sec | User configurable ramp up rate in dB/sec | | Sine-on-Random Control Software | | Independent no. of Sine tones | 1 to 8 | 1 to 10 | 1 to 10 | | Drive Signal | Multiple analog sweeping sine tone combine with continuous broadband Gaussian random | Multiple analog sweeping sine tone combine with continuous broadband Gaussian random | Multiple analog sweeping sine tone combine with continuous broadband Gaussian random | | COLA output for Sine tone | —- | 1 | 1 | | Sweeping | Fixed sine tones | Fixed/ sweeping | Fixed/ sweeping | | Sweep Rate | —- | Oct/min or Hz/sec or time/sweep | Oct/min or Hz/sec or time/sweep | | Stat frequency | Any value between the available frequency range | Any value between the available frequency range | Any value between the available frequency range | | Start direction | —- | Up/down | Up/down | | Sine tone level | Constant Acceleration | Constant Acceleration | Constant Acceleration | | Run Schedule | Variable pre-test level & duration | Variable pre-test level & duration Broadband random on/off Sine on/off per tone Start sweep per tone | Variable pre-test level & duration Broadband random on/off Sine on/off per tone Start sweep per tone | | Safety | Alarm/Abort limits | Alarm/Abort limits User configurable ramp up rate in dB/sec | Alarm/Abort limits User configurable ramp up rate in dB/sec | | Storage of Test Data | To disk at pre-configured intervals in tabular text format & waveforms | To disk at pre-configured intervals in tabular text format & waveforms | To disk at pre-configured intervals in tabular text format & waveforms | | Storage of Test Graph | Storage of waveform into user defined file. Export of test graph to Microsoft Office | Storage of waveform into user defined file. Export of test graph to Microsoft Office | Storage of waveform into user defined file. Export of test graph to Microsoft Office | | Posttest Report Generation | Facilitates report generation of test conducted. Export of graph to Microsoft Office | Facilitates report generation of test conducted. Export of graph to Microsoft Office | Facilitates report generation of test conducted. Export of graph to Microsoft Office | Safety features/ Protections | Loop check feature thru Pre-test to verify physical setting of the system before starting actual test. Independent alarm and abort profile in terms of ± (1.0 to 50.0 %) of reference pulse acceleration. Auto test shutdown in case of control exceeding the abort limit or lines exceeds for set no. of loops. Limiting abort level Grms on each channel. Password authorization to operate the software. | Loop check feature thru Pre-test to verify physical setting of the system before starting actual test. Independent alarm and abort profile in terms of ± (1.0 to 50.0 %) of reference pulse acceleration. Auto test shutdown in case of control exceeding the abort limit or lines exceeds for set no. of loops. Limiting abort level Grms on each channel. Password authorization to operate the software. | Loop check feature thru Pre-test to verify physical setting of the system before starting actual test. Independent alarm and abort profile in terms of ± (1.0 to 50.0 %) of reference pulse acceleration. Auto test shutdown in case of control exceeding the abort limit or lines exceeds for set no. of loops. Limiting abort level Grms on each channel. Password authorization to operate the software. | | | | | | | |